Stainless steel inspection tables with black and white backgrounds and an optional hooded LED light, for QA and QC checks by eye.

A particle that a quick glance misses shows up against the right background under steady light. An inspection table gives the operator both: a black panel for light-coloured particles and fibres, a white panel for dark specks, and a hooded light over the work.

We make inspection tables in SS 304 stainless steel with a matt or mirror finish, stiffened under the top so it stays flat, and sized to the work and the room. Wheels can be fitted where the table moves between rooms.

  • Semiconductor and electronics assembly and test areas
  • QA and QC areas in pharma and biotech plants
  • Production and granulation areas
  • Laboratories
  • Food processing plants

A sample drawing. Yours is drawn to your room and equipment.

HWHoodLED lightBlack panelWhite panelUndershelf
Product
Visual inspection tables
Family
Cleanroom furniture
Drawing
General arrangement
Scale
Not to scale

The decisions that set the size and price. Answer what you can; we confirm the rest with the quotation.

Backgrounds
Black shows up light particles and fibres; white shows up dark specks. Most procedures check each unit against both, so specify the two panels side by side.
Lighting
Inspection procedures set a light level at the inspection point. Tell us the lux figure your SOP works to, so the light and hood are chosen to reach it.
Size & height
Length sets how many operators work at the table; height depends on whether they sit or stand. Give us both, and the chair or stool they will use.
Fixed or mobile
Fixed legs for a dedicated inspection room; wheels where the table moves between rooms.
Finish
A matt finish reflects less of the inspection light back at the operator than a mirror finish.

Our standard build. Anything outside it can be made to order.

MaterialSS 304 stainless steel
FinishMatt or mirror
BackgroundsBlack and white acrylic panels
LightingLED light with hood (option)
FrameStiffener under the top shelf
MobilityFixed legs or wheels
SizesMade to your size

Why does an inspection table have a black and a white background?

Light-coloured particles and fibres stand out against black, and dark particles and specks against white. Checking each unit against both catches defects that one background alone would miss.

How bright should the inspection light be?

Your procedure sets the figure. Pharmacopoeial guidance for manual inspection of injections uses 2,000 to 3,750 lux at the inspection point. Tell us the level you work to and the light is chosen to reach it.

Can you make the table to our size?

Yes. Tell us how many operators use it, whether they sit or stand, and the room it goes in, and we will quote a table to suit.

Quantity, sizes and where it will be used are enough to start. A sketch or photo of the space helps.